When the next “Update Driver Software – Demo2X” dialog appears, scroll down and select “Universal Serial Bus controllers”: Note: if this dialog doesn’t appear and instead a dialog titled “Update Driver Software – Aptina Imaging Demo2X Board” appears, this indicates that another Aptina USB driver has been previously installed. 1/2.5 inch Aptina CMOS sensor (MT9P031). 2,592×1,944 (5 MP), up to 15 fps. Rolling shutter. Trigger and I/O inputs. Manufactured by The Imaging Source. Windows and Linux software included. USB 3.0 color industrial camera. This information is relevant only to customers and channel partners conducting business with Aptina Imaging. ON Semiconductor completed the Integration of Aptina Imaging Business Systems and Processes. Changes will become effective on Monday, June 1, 2015. ON Semiconductor acquired Aptina Imaging in August of 2014.

This document will provide complete installation instructions for the Demo3 interface board. It is intended for internal Aptina usage and assumes access to the purchase/request system and internal servers.

It is recommended to acquire the following items prior to starting the installation:

  • USB 3.0 adapter card and driver
    • Necessary if your PC does not have a built in USB 3.0 host controller.
    • Order through your site's purchasing process. Use the guidelines covered by the 'Demo3 – USB 3.0 Host System Selection' document.
  • USB 3.0 cable
    • Order through your site's purchasing process.
  • Demo3 interface board
    • Baseboard silkscreened: 'DEMO3 REV2 AGB1N0CS'
  • Adapter for Demo2 style headboards (optional)
    • Necessary if using existing headboards with the legacy connector (26 or 26+13pin interface).
    • Silkscreened: 'AGB2N0CS DEMO 2 HB TO DEMO 3 ADAPTER REV2'
  • CAT6 cable(s) (optional)
    • Necessary if using Demo3 style headboard that supports CCP, MIPI or HiSPi.
  • DevSuite installation file
    • Release 4.4.2 or later.
  1. Install DevSuite onto the target system by running the installation (setup.exe) file. During the installation process, the Demo3 driver files for various operating systems will be copied for later use. Please be aware that this does not actually 'install' the driver. Installation will occur at a later step, but it will be useful to note the locations and structure of the 'drivers' folder.


For Developer builds, the default location is:
C:Aptina Imaging Devdrivers
For External builds, the default location is:
C:Aptina Imagingdrivers
The sub-folder structure will break out into the individual operating system versions that are supported:
Demo3 - Installation Guide > worddav1a3cb5a62b8910f3d0c39f688da84e6c.png'>

2. When the installation is complete, power down the system if you need to install a USB 3.0 PCIe adapter card. If installing an ExpressCard adapter the laptop does not need to be shutdown. If the system already comes with a USB 3.0 host adapter skip ahead to Demo3 Assembly.

3. Consult the instructions supplied with your USB 3.0 adapter. These generally encompass the following steps:

a. Hardware installation consisting of placing the adapter card into a free slot.

Tip #1: From our experience with various NEC/Renesas based PCIe adapters, it has been noted that these designs typically have a supplemental power connector on the board. This connector is usually a 4-pin Molex (legacy hard drive) or 4-pin Berg (floppy drive) type:
Demo3 - Installation Guide > worddav57b341b9278785f35de66863de0ff3bc.png'> Demo3 - Installation Guide > worddav56399bd362d697c7926c8f2e2cf81be0.png'>
In some cases, the system may not have any available power connectors. While in others cases, they may not be the appropriate type or no adapter is available. In these situations, some users have forgone this power connection with no ill effects, so it may not be 100% necessary. However, you will need to test if this works for your particular setup.

b. Reboot system.

c. Driver installation Rndis ethernet gadget driver windows 7 download.

Download Aptina Imaging Migmate Board Drivers

Imaging

Tip #2: The drivers packaged with the adapter may be out of date. It is strongly recommended to download the latest drivers for your particular adapter. A ZIP file containing the latest drivers for various USB 3.0 vendors are found here.

d. Firmware update – Only known affect NEC/Renesas based adapters. These designs have programmable firmware which may also be out of date. It is recommended to check and update if necessary.

Tip #3:
Demo3 - Installation Guide > worddavba3bf50b12354c050d4382d4639844ca.png'>
Run the NEC/Renesas utility, typically located at:
C:Program Files (x86)Renesas ElectronicsUSB 3.0 Host Controller DriverApplicationnusb3utl.exe
Or for older versions of software:
C:Program Files (x86)NEC ElectronicsUSB 3.0 Host Controller DriverApplicationnusb3utl.exe
Demo3 - Installation Guide > worddav0d5ccd4611c5f772dd0fa1b60bb18a92.png'>
Since there are different generations of NEC/Renesas parts, there are different corresponding firmware versions for each.
μPD720200:
Uses 3xxx series firmware, recommend version 3028 or later
μPD720200A
Uses 4xxx series firmware, recommend version 4015 or later
μPD720201 / μPD720202
Uses 2xxx series firmware, recommend version 2017 or later
The latest NEC/Renesas FW in the ZIP file found here, in 'Renesas_(NEC)'. Demo3 Assembly
Demo3 - Installation Guide > worddav582707aa6187e071084331e6e3b51464.png'>
The Demo3 interface board utilizes a new sensor headboard interface that supports parallel, CCP, MIPI, and HiSPi interfaces through a single connector. Due to this design, all new headboards will be designed for the Demo3 interface. As of September 2012 there are two headboards using this interface, the AR0833 and AR1330. If you are using either of these sensors, assembly involves simply connecting the headboard to the Demo3.
Demo3 - Installation Guide > worddav01e749d18f806e62f0bf80336b84b7d2.png'> Demo3 - Installation Guide > worddav72f9972bb6e5cc3ae8345ed6f65f7c93.png'>
Demo3 interface board AR0833 + Demo3 interface board
The Demo3 also supports headboards designed for the previous Demo2/Demo2X interface boards. A Demo2 headboard to Demo3 adapter must be used in this case. The adapter provides the legacy 26 + 13 pin parallel headers and two RJ-45 jacks for the CCP, MIPI or HiSPi connections. Assembly consists of connecting the headboard to the adapter; and then connecting the adapter to the Demo3.
Demo3 - Installation Guide > worddav1e2c353cb59756471096559a7db2c9aa.png'> Demo3 - Installation Guide > worddav00ce3f184b5915e6ac1d4b549448e09e.png'>
D2 headboard to D3 adapter A-14041 HiSPi + D2-D3 adapter + Demo3 interface board

At this point your Demo3 assembly is ready to be connected to the PC. Take a USB 3.0 cable and connect the between the Standard-A receptacle on the Demo 3 interface board and the Standard-B port on the USB 3.0 host.
While most USB 3.0 host configurations will supply 2 or more ports, we recommend that the Demo3 be the only the device connected for power and performance concerns. Other USB devices that do not require USB 3.0 performance (i.e. mice, keyboards, etc.) should be attached to available USB 2.0 ports when possible.

Notes on Cables

  • USB 3.0 cables are different than USB 2.0 cables. A cable designed specifically for USB 3.0 must be used to achieve the Demo3's full bandwidth potential. Below USB 3.0 cable plugs are shown on the left of each picture while USB 2.0 cable plugs are shown on right. Note the additional height of the USB 3.0 Standard-B (left image):

Demo3 - Installation Guide > worddav8a2b0aa79883ff06f30d4a9e27721608.png'> Demo3 - Installation Guide > worddavd10131b341116e2af3d90c4673d4e6f6.png'>

  • USB 3.0 cables will also use the blue color coding within the plugs and be labeled accordingly on jacket. The jacket color may be any color (blue, black , etc.)
  • USB 3.0 cables contain more internal elements than USB 2.0 cables. There are more signal wires and additional shielding which in turn creates a stiffer cable. Extra care must be taken with these cables, try to avoid complex or tight radius bends over short distances of cables. Do not tie knots with or fold the cable onto itself, rather gradually coil the cable:

Demo3 - Installation Guide > worddavc30eefca0efa8836b61f7752777adf2b.png'> Demo3 - Installation Guide > worddav37a15d9f6c905e56fa6198f5decb3d94.png'>
This will prevent internal breakage, which will cause various performance issues with the Demo 3 camera system.

  • It is possible to use a USB 2.0 cable between the Demo3 and USB 3.0 host. However, performance will be limited to USB 2.0 bandwidth as the SuperSpeed lanes of the cable are not being used. This usage is not recommended, but may be useful for troubleshooting or in event a USB 3.0 cable is not readily available.

Notes on USB 3.0 Receptacles/Ports

  • If you have installed an add-in USB 3.0 host adapter it should be fairly obvious which ports to use. For systems that have a built in USB 3.0 host, there is likely to be a USB 2.0 host too. The USB 3.0 ports will typically use the blue color coding, while the USB 2.0 ports will have the traditional black color coding. Some manufacturers opt not to use the color coding, in these cases the USB 3.0 port may be identified with the SuperSpeed logo and/or labeling.


Demo3 - Installation Guide > worddavc519d1855f1da2b2a08d33b08ed43762.png'> Demo3 - Installation Guide > worddavbef1df838268a58c86d69ae3cda25d07.png'>

  • It is possible to connect the Demo3 assembly to a USB 2.0 host with either cable. However, performance will be limited to USB 2.0 bandwidth. This usage is not recommended, but may be useful for troubleshooting issues with the USB 3.0 host.

Download Aptina Imaging Migmate Board Driver License

Once connected, the Windows operating system will detect the Demo3 and attempt to install an appropriate driver. If one is not found, it will prompt for a driver location. Demo3 - Installation Guide > worddav708473eece4a8af5ca8e17c79a9b24db.png'> to the locations noted earlier and path to the folder that suits the flavor of Windows you use (Windows7 dialogs shown):
Demo3 - Installation Guide > worddav128ace1fc72f295e36b6e8a6389ab0db.png'> Demo3 - Installation Guide > worddav209d6fee01a6dad84b3320bb10147017.png'>
Demo3 - Installation Guide > worddavb14ca5a709fcbb6a0fc841314ae2cb8a.png'>
Tip #1: If the driver search was aborted, you can always go back and:

  1. Open the Device Manager.
  2. Expand the 'Other devices' section and locate the 'DEMO3' entry:

Demo3 - Installation Guide > worddav926f30d73bbea3e94b9af398eb6436e6.png'>

  1. Then right-click the DEMO3 entry and select the 'Update Driver…' option and follow the prompts.


Tip #2: Windows7 will attempt to search the Windows Update site for a driver. If your system is behind the Aptina corporate firewall, Windows Update will be blocked and this action will eventually timeout and fail. To save a few minutes of your time, click the bubble that appears on the taskbar:
Demo3 - Installation Guide > worddavc08b2f733dfb259979767a82cef1fefe.png'>
Next click 'Skip obtaining driver software from Windows Update':
Demo3 - Installation Guide > worddavd1dd6fa81a57b1f66db8305896d9c738.png'>
Click 'Yes' on the 'Driver Software Installation' dialog:
Demo3 - Installation Guide > worddavc922bebdc8c198c657de944830cc359b.png'>
Then begin the 'Update Driver Software…' process described in Tip #1.
Tip #3:
The Demo3 Team has uploaded Windows7 drivers for the Demo3 to the Windows Update site. Users, who have internet access that does not block the Windows Update site, will automatically have drivers installed for them.
Tip #4:
To confirm the Demo3 driver installation:

  1. Run the Device Manager.
  2. Expand the 'Universal Serial Bus controllers' section.
  3. Then check for the 'Aptina Demo3' (making note of any error codes/warnings):

Demo3 - Installation Guide > worddava5d75be30781f2956bdf17c7462c0e8f.png'>

Please contact Email imaging_demo_bugs@aptina.com.

  • Linux Support from the Manufacturer
  • Board and Housed Cameras
  • USB and GigE Interfaces
  • Open Source Software
  • Apache License 2.0
  • Get Involved at GitHub

Simple Integration into Cost-Sensitive Linux Applications

The Imaging Source board and housed cameras have been designed to be cost-effective components for industrial, medical and scientific imaging applications. They are available with USB, GigE and FireWire interfaces, and ship with CCD or CMOS sensors from Sony or Aptina.

The Imaging Source authors and fully supports open source drivers and software − released under the Apache License 2.0 − to integrate its industrial, medical and scientific cameras into popular distributions, such as Debian, Ubuntu, CentOS and Red Hat. Download or fork the source code at GitHub.

Camera features, such as global and rolling shutter, gain, exposure and white balance can be directly accessed via the supplied API. Many camera models offer trigger input and digital I/Os in addition.

Download Aptina Imaging Migmate Board Driver Download

Included software for Windows and Linux

The following software for Windows and Linux is included free of charge:

  • Drivers for Windows XP, Vista, 7, 8 and 10 XP, Vista, 7/8/10 drivers for DirectShow, DirectX, TWAIN, VfW, WDM, HALCON, MERLIC, LabVIEW, MATLAB & NeuroCheck.
  • Linux support The Open Source project tiscamera supports The Imaging Source image capture devices (cameras, frame grabbers etc).
  • IC Imaging Control SDK consisting of a .NET and ActiveX component and a C++ class library for Windows XP, Vista, 7 and 8.
  • IC Capture, IC Measure and IC Barcode Camera control, image acquisition, on-screen measurement and barcode software for Windows XP, Vista, 7, 8 and 10.

Do not hesitate: Fill in the above contact form to speak with our Linux engineers today.

About The Imaging Source

Established in 1990, The Imaging Source is one of the leading manufacturers of industrial cameras, frame grabbers and video converters for production automation, quality assurance, logistics, medicine, science and security.

Our comprehensive range of cameras with USB 3.1, USB 3.0, USB 2.0, GigE interfaces and other innovative machine vision products are renowned for their high quality and ability to meet the performance requirements of demanding applications.

Comments are closed.